Technical Drawings

Specifications

WIDTHNORMALLY 1200 MAX (NOTE: FEWER PANELS = LOWER COSTS)   
Thickness (mm)RwStandardFinelineOverlay
70 Series36 - 42*70- 82
100 Series (*45-47)42-50100100112

Wall Weights
Basic panel excluding heavy finishes and retractable seals.

 Face363942454750
70Board28294454
Plaster274251
100Board304554
Plaster284454
Steel54

Structural Support
Tracks can be supported directly from a steel beam or from a concrete soffit using hanging rods. Beams below are a guide, consult an engineer on specifics.

HeightRwSpan 4m6m8m10m
2.742150UB14/150PFC 200UB25/230PFC 310UB40/300PFC 410UB54
47150UB14/150PFC 250UB25/250PFC 310UB46/380PFC 460UB67
3.0 42150UB14/150PFC 200UB25/230PFC 310UB40/300PFC 410UB60
47150UB14/150PFC 250UB25/250PFC 360UB45/380PFC 460UB67
3.6 42150UB14/150PFC 250UB25/250PFC 310UB46/380PFC 460UB67
47150UB18/150PFC 250UB31/250PFC 360UB51/380PFC 460UB75

Walls over 3.6 m require specific calculations.

CAD Drawings

Drawings on headworks, panel sections and cupboards can be downloaded for use in your own CAD system.